- The VDA published ISA2027 on July 1, 2026. The catalogue replaces ISA 6.0.3 and, according to ENX, applies to all TISAX assessments ordered from January 1, 2027. What counts is the order date, not the audit date.
- Existing labels stay valid until they expire, and the validity period remains up to three years. ISA2027 only affects you when you order your next assessment.
- Version numbers are gone. From now on the catalogue carries the year from which it applies to newly ordered assessments, and it is published every summer.
- The main content changes are stricter supply chain requirements for high protection needs, restructured prototype protection (five control groups become two), and updated references: NIST CSF 2.0 and ISO/IEC 27001:2022.
- If your label expires in the first half of 2027, you need to decide by the end of 2026 whether to order under ISA 6.0.3 or plan for the new catalogue. Either way, you need an early slot with your assessment provider.
The questionnaire that every TISAX assessment is based on is getting a new name and new content: ISA2027 replaces ISA 6.0.3. If your label is about to expire or your customer requires an initial assessment, you need to know which catalogue applies to you, what changes in it, and when you have to act. This article covers the documented changes, a timeline, and a checklist for the transition.
The basics of TISAX, meaning assessment levels, maturity levels, and the process, are covered in the article on TISAX certification for automotive suppliers. This article only deals with what is new in ISA2027.
What is ISA2027 and when does the catalogue apply?
ISA2027 is the new edition of the VDA ISA questionnaire (Information Security Assessment). The VDA published it on July 1, 2026, and the ENX Association confirmed this on its website the same day. ENX administers TISAX and runs the portal through which assessments are ordered and results are shared.
The key sentence is in the ENX announcement: ISA2027 applies to all TISAX assessments ordered from January 1, 2027. That is not the same as "assessments that take place from 2027". Many vendor blogs are imprecise here. You will find sentences like "mandatory for assessments from January 1, 2027", which sounds like the audit date. According to ENX, the order date is what counts.
The key facts
| Item | Status according to ENX (October 2026) |
|---|---|
| Publication | July 1, 2026 |
| Predecessor | ISA 6.0.3 |
| Applies to | all TISAX assessments ordered from January 1, 2027 |
| Existing labels | remain valid for their full validity period |
| Label validity | still up to three years |
| Future rhythm | annual publication in summer, effective from January 1 of the following year |
You already know the six months between publication and cut-off date from the last switch. ISA 6 was published in October 2023 and became mandatory on April 1, 2024, as ComConsult also describes. Back then, assessments ordered by the end of March 2024 could still run on the previous version. The pattern is familiar, only the cut-off date now falls on the start of the year.
Why is the catalogue not called ISA 7?
ENX and the VDA abolished version numbers. From now on, the catalogue carries the year in which it takes effect for newly ordered assessments. ISA2027 is published in 2026 and applies from 2027, and the next catalogue is due in summer 2027 and takes effect in 2028. If you search for "VDA ISA 7" or "new TISAX version 2027", you mean the same document. This rhythm replaces the previous irregular jumps from one major version to the next.
ENX explicitly states that the annual catalogue does not mean an annual reassessment. The reassessment frequency does not increase, and label validity stays at up to three years.
Who needs to do what now?
Not everyone needs to act right now. It depends on where you are in the TISAX cycle.
| Your situation | What it means | Next step |
|---|---|---|
| Label valid, expires no earlier than end of 2027 | ISA2027 only applies to your next assessment | Read the catalogue, estimate gaps roughly, set aside budget for changes |
| Label expires in the first half of 2027 | You decide by year-end: order under ISA 6.0.3 or under ISA2027 | Clarify the date with your assessment provider, start the gap analysis |
| Initial assessment pending, not yet ordered | If you order from January 1, 2027, ISA2027 applies | Decide whether to order in 2026 or build on ISA2027 right away |
| Assessment already ordered | This follows from the cut-off date and several assessment providers describe it that way: it continues under ISA 6.0.3 | Have your provider confirm which catalogue is stated in the order |
Renewing a label: what does that mean for TISAX?
A TISAX label is not extended, it is renewed. Before it expires, you go through a new assessment based on the catalogue that applies at the time of the order. So if you renew your label in spring 2027 and place the order in January, you are already working with ISA2027. If you plan the renewal for autumn 2027, ISA2027 applies anyway. The "renewal" is therefore also a question of when you place the order.
Initial assessment: build on ISA2027 right away?
If your customer requires a label and you are starting from scratch, the road takes several months anyway. That includes building an ISMS based on ISO 27001, which forms the basis for TISAX. Your assessment will then very likely take place after the cut-off date. Align with the ISA2027 catalogue from the start instead of building on ISA 6.0.3 and reworking later.
What changes compared with ISA 6.0.3?
The catalogue is not a reinvention. The modules Information Security, Prototype Protection, and Data Protection remain, and the structure stays recognizable. The changes concentrate on a few areas. The following table shows what can be documented, and which source documents it.
Old vs. new at a glance
| Area | ISA 6.0.3 | ISA2027 | Source |
|---|---|---|---|
| Naming | version number | year from which the catalogue applies to newly ordered assessments | ENX |
| Rhythm | irregular major versions | annually in summer, effective from January 1 of the following year | ENX |
| Label validity | up to three years | unchanged | ENX |
| References | mappings to ISO/IEC 27001, including the 2013 edition, and NIST CSF 1.1 | ISO/IEC 27001:2022, NIST CSF 2.0, and ISA/IEC 62443; references to ISO 27001:2013 are removed | ENX for NIST CSF 2.0 and ISO 27001:2022; removal of the 2013 edition according to Valiido, Syngenity, and Azena |
| Supply chain | control 1.2.4 | control 6.1.3 in the supplier chapter; documented review of evidence for high protection needs | ENX for the content; numbering according to Valiido and 360dt |
| Prototype protection | five control groups (8.1 to 8.5), 22 controls | two areas (8.1 organizational, 8.2 physical and environmental), 20 controls | ENX for five to two; number of controls according to Valiido and 360dt |
| Information security | 46 controls | still 46 controls, with revised wording in 44 of them; several should-requirements become must-requirements (for example 1.1.1 and 4.1.2) | 360dt and Valiido |
| Incident and crisis management | chapter 1.6 | chapter 1.6 revised | 360dt and the ISA analysis by Cagri Polat |
| Teleworking | chapter 2 | requirements tightened | Valiido and 360dt |
| Data protection | 12 controls | 12 controls, unchanged | 360dt and Valiido |
A note on the table: ENX describes the broad lines in its announcement. Control numbers, counts, and individual must-requirements come from analyses by assessment providers and consultants. Check them against the catalogue itself before using them in your gap analysis. You get the catalogue through ENX and the VDA, and you can find the ENX announcement this article relies on at enx.com.
Supply chain: this is where most of the effort is
ENX names the supply chain as the first content topic. Organizations with high protection needs have to do more to document, review, and monitor whether their suppliers meet the requirements. For very high protection needs, clients expect their suppliers to provide a TISAX label, an equivalent third-party assessment, or an appropriate supplier audit.
For you as a supplier, that means you are both the audited supplier and the client. Your customer asks for your label. And you have to show that you review your own service providers, such as the IT operator, the cloud provider, or the logistics partner that transports prototype parts. Several analyses report that for high and very high protection needs, you must review documented security evidence from your suppliers, and that significant changes at the supplier trigger a new review.
What does that mean in practice?
- A supplier list with the protection need of the data each provider processes.
- One piece of evidence per supplier: label, certificate, audit report, or a completed security questionnaire.
- A review date and a rule for what happens when something significant changes.
- A supplier security policy that sets these expectations in writing.
If you use cloud services for automotive data, there is another axis to check. The BSI requirements for cloud providers, which are being rewritten with BSI C5:2026, give you a solid basis for evidence.
Prototype protection: from five to two
If your scope includes prototype protection, the effort is distributed differently after the switch, but not necessarily smaller. ENX writes that the five control groups of the previous module were merged into two areas: organizational requirements, and physical and environmental security. According to Valiido and 360dt, the number of controls fell from 22 to 20. According to Syngenity and Azena, the merge added requirements for traceability of prototypes across their lifecycle, including return, recycling, disposal, or destruction at the end.
Merging changes the numbering. Evidence you filed in your self-assessment under 8.3 or 8.4 has to be reassigned. Which measures change in substance, for example for access control, photography bans, or transport, only becomes clear when you compare against the catalogue. For the physical parts, it helps to look at the requirements for physical security under ISO 27001, because many measures overlap.
Information security: wording and must-requirements
In the Information Security module, the number of controls barely changes, but the text does. According to the 360dt analysis, 44 of 46 controls were editorially revised. That is less dramatic than it sounds: the catalogue sharpened formulations, defined terms such as project, event, and incident more precisely, and cleaned up historical inconsistencies. ENX confirms a comprehensive review of wording and translation.
You should still check two things:
- Should becomes must. According to Valiido and 360dt, some previous recommendations now apply as mandatory. The examples named are password requirements (4.1.2) and the availability of policies (1.1.1). If you previously documented maturity level 2 there by pointing to "recommendation", you now need an implementation.
- "Aspects are taken into account". Syngenity points out that this phrase in the catalogue now means you demonstrably evaluated every aspect mentioned. You document either the implementation or a justified exclusion. A blanket "taken into account" no longer satisfies the assessor.
What stays the same
According to 360dt and Valiido, the data protection section is identical to ISA 6.0.3. There are no indications in the ENX announcement or in the analyses of changes to maturity level scoring, to assessment levels AL1 to AL3, or to mutual recognition. An existing ISMS based on ISO 27001 also remains the supporting foundation. With the new references to the 2022 edition and the removal of the 2013 edition, a legacy issue also disappears, because certificates under ISO 27001:2013 have no longer been valid since October 31, 2025.
How do you plan the transition?
Planning starts with a decision: do you order your assessment in 2026 under ISA 6.0.3, or only in 2027 under ISA2027? That is neither a matter of convenience nor an evasive maneuver. It is a question of scheduling.
Order in 2026 or plan for ISA2027?
| Criterion | Order by December 31, 2026 (ISA 6.0.3) | Order from January 1, 2027 (ISA2027) |
|---|---|---|
| Catalogue | known, your evidence is built on it | new, gap analysis needed |
| Preparation | often shorter if your label expires soon anyway | longer, especially for supply chain and prototype protection |
| Risk | The assessment provider has no slot left before year-end; ordered is not audited | The label expires before the assessment is complete |
| Long term | next assessment usually after three years, then under whichever catalogue applies by then | you build right away on the catalogue that will shape the coming years |
The obvious reflex is: "I'll just order quickly in 2026 and avoid the new requirements." That only works in the short term. The requirements catch up with you at the latest at your next assessment under the catalogue that applies then, and your customers may already be asking for supply chain evidence. Ordering in 2026 makes sense if your label expires early in 2027, your assessment provider has a slot, and your evidence for ISA 6.0.3 is current.
Whether an order placed in 2026 has to be carried out by a certain date is not stated in the ENX announcement. Ask your assessment provider in writing which catalogue is stated in your order and whether there is a deadline for the audit date.
Gap analysis in four steps
With a gap analysis, you compare your current state with the requirements that have changed. For ISA2027, proceed like this:
- Download the catalogue and secure the version. Download ISA2027 from ENX or the VDA and file the version with its date. That lets you trace later corrections.
- Focus areas first. Check the chapters where the changes are concentrated: chapter 1 (policies, incident and crisis management), chapter 2 (teleworking), chapter 6 (suppliers), and, if in scope, chapter 8 (prototype protection). That covers the largest changes.
- Compare the rest line by line. Because the wording was adjusted in almost all controls, a glance at the headings is not enough. Read the controls where you previously had maturity level 2 or a borderline 3 in the new wording.
- Assess gaps and plan. For each gap: measure, owner, due date, evidence. The sequence follows from the date of the assessment, not from the chapter.
If you maintain your SoA and measures in your ISMS, you can run the gap analysis directly there. In ISMS Lite, every control gets an implementation status, maturity level, due date, and linked evidence, and open points show up as measures with owners and deadlines. The ISA2027 catalogue is available there as a framework, so you can run the gap analysis directly against the new requirements.
Suggested timeline
The following plan assumes a start on October 5, 2026 and a label that expires in the first half of 2027. It is a suggestion, not an ENX requirement. Adapt it to your expiry date.
| Period | Step | Result |
|---|---|---|
| October 2026 | Download ISA2027, review changes, clarify label expiry date and customer requirement | Basis for the decision |
| October to early November 2026 | Ask the assessment provider: available slots, catalogue in the order, order date | Offer with dates, decision 2026 or 2027 |
| November 2026 | Gap analysis in the focus chapters, supplier list with protection needs | Prioritized list of gaps |
| December 2026 | Place the assessment order if you chose the 2026 route; otherwise approve the measure plan | Order placed or plan approved |
| January to March 2027 | Close gaps: collect supplier evidence, adapt policies and teleworking rules, reassign prototype protection | Evidence generated in operation |
| March to April 2027 | Internal audit and updated self-assessment based on the applicable catalogue | Maturity levels evidenced, remaining gaps known |
| Before the label expires | Assessment, closing meeting, evidence for open points | New label |
As a rule of thumb, you need a few weeks between implementation and assessment in which the processes run and evidence accumulates. As with every TISAX project, maturity level 3 only counts if the assessor sees lived practice rather than freshly approved papers.
The assessment slot with your provider
The date is the bottleneck, not the gap analysis. Assessment providers plan their auditors based on requests. It seems likely that orders pile up around the turn of the year because many companies push the decision to the cut-off date. That is not documented, but the risk is real: if you only ask in December, you may not get a slot before your label expires. How long the lead time is at your provider, only they know. As a planning assumption: ask now, not only after the gap analysis.
Clarify five points when you ask:
- Which catalogue is stated in the order, and will that be confirmed in writing?
- What is the earliest possible audit date, and how many days are planned?
- Are there preliminary talks about the gap analysis, and what do they cost?
- How does the assessment work if prototype protection is in scope?
- What happens if the date falls after the expiry date of the label? How do customers handle that?
It is best to also clarify the last point with your customer. Some clients tolerate a short gap while an assessment is under way, others do not. That is not in the catalogue, it is in your supply contract and in the customer's requirements.
Example: a supplier with 110 employees
Take a manufacturer of turned and milled parts with 110 employees, one site, and an AL3 label covering information security and prototype protection. The label expires at the end of May 2027. The main customer is a tier 1 supplier that requires high protection for design data.
In October, the information security officer reviews the catalogue and notices three things. First, the company has 14 service providers but documented evidence for only two. Second, the photography ban in the prototype room sits in a policy that runs under a different number after the restructuring. Third, the password policy only contains recommendations for minimum length.
She requests an offer from the assessment provider. The provider has a slot in April 2027 but none in December. That settles the decision: order in January under ISA2027, assessment in April. The gap analysis is ready by the end of November, and in December management approves the measure plan. The IT provider supplies its certificate, the security questionnaire goes out to the freight carrier, and the password policy becomes binding. In March, an internal audit checks the changes, and in April the external assessor arrives.
The example is constructed, but close to what a mid-sized company can manage: the effort is not in rebuilding, but in three to five targeted improvements and an early booked date.
How do TISAX and other requirements fit together?
Many automotive suppliers also fall under NIS2 because they belong to manufacturing. That changes nothing about the catalogue, but it changes your planning: the supplier reviews that ISA2027 demands more strongly also help with your NIS2 evidence. How to demonstrate effectiveness to the BSI is explained in the article on NIS2 evidence and audits. Which standard covers what is shown in the frameworks comparison.
The documented changes in ISA2027 contain no connection to AI topics. No AI-specific requirements appear in the analyses or in the ENX announcement.
What remains open? Status October 2026
Two points cannot be documented, so I name them openly.
Transition rules in detail. The ENX announcement names the cut-off date for the order. It does not say whether an order placed in 2026 has to be carried out by a certain date. Older vendor articles even write that the cut-off date is not yet known. Those statements are outdated. Rely on the ENX announcement and the written confirmation from your assessment provider.
Details of the controls. Figures such as 22 to 20 controls in prototype protection or 44 revised controls come from vendor analyses. They look plausible because several sources agree. ENX itself only says "five control groups become two". Count in the catalogue before you estimate effort.
This is not legal or certification advice. ENX gives the binding information on the catalogue, and your assessment provider on your order.
Checklist: transition to ISA2027
Decision and date
- Expiry date of your TISAX label noted
- Customer requirement clarified (assessment level, scope, deadline)
- Decision made: order in 2026 under ISA 6.0.3 or in 2027 under ISA2027
- Assessment provider contacted, date and catalogue in the order confirmed in writing
- Provider asked whether there is a deadline for carrying out an order placed in 2026
Gap analysis
- ISA2027 downloaded from ENX or VDA, version and date filed
- Chapters 1, 2, 6, and if applicable 8 checked in the new wording
- Controls with maturity level 2 or borderline 3 reassessed in the new wording
- Previous "should" recommendations checked for new must-requirements (for example password requirements, policy availability)
- Mappings to ISO 27001:2022 and NIST CSF 2.0 adapted in your documents, references to ISO 27001:2013 removed
Supply chain
- Supplier list with protection need of the processed data created
- One piece of evidence per supplier on file (label, certificate, audit report, questionnaire)
- Review date and rule for significant changes defined
- Supplier security policy updated
Prototype protection (if in scope)
- Evidence reassigned to the new areas 8.1 and 8.2
- Traceability of prototypes across the lifecycle checked, including return, recycling, and destruction
- Transport and access rules compared against the new wording
Evidence and assessment
- Measure plan with owners and due dates approved
- Internal audit carried out based on the applicable catalogue
- Self-assessment updated
- Evidence organized so the assessor can find it during the session
Common mistakes when switching to ISA2027
Misreading the cut-off date. "From January 1, 2027" means, according to ENX, from the order date. If you rely on an audit date, you plan with the wrong catalogue. Have the catalogue in your order confirmed in writing.
Ordering quickly in 2026 without a slot. An order without a reliable audit date only postpones the problem. If the assessor only comes after the label has expired, you have neither used the old catalogue nor saved the label.
Checking only the obvious. If you focus only on prototype protection and supply chain, you overlook that the wording changed in almost all controls of the Information Security module. Maturity level 2 controls in particular slip through otherwise.
Suppliers without protection needs. A supplier list without a link to the data processed does not help the assessor. For high protection needs, the evidence counts, not the list of names.
Vendor blogs as a source. Statements about ISA2027 diverge, and some texts cite outdated states. Work with the catalogue and the ENX announcement, and treat vendor analyses as orientation.
Conclusion: secure the date first, then close the gaps
ISA2027 is an update, not a restart. The changes are manageable, but they hit the parts that take the most time: supplier evidence, prototype protection, and the new wording. This week, find out when your label expires, get a date from your assessment provider, and have the catalogue in your order confirmed. Track the gaps as measures with owners and deadlines, so the assessor sees who finished what by when.
Further reading
- TISAX Certification: Requirements, Process, and Assessment for Automotive Suppliers
- Which Frameworks Do I Need? NIS2, ISO 27001, BSI IT-Grundschutz, TISAX Compared
- Protection Needs Assessment: Evaluating Confidentiality, Integrity, and Availability
- Supplier Assessment with Security Questionnaires: Template and Approach
- Evaluating Audit Findings and Deriving Actions